ACM™-600 +24 VDC
600 Amp Power Plant, PDS 4100
 
  Product Resources
Literature
  #10-958 (PDF 108KB) Low Res
  #10-958 (PDF 1.32MB) High Res
Product Manual
  PM990.4100.00 ACM 600 (PDF 304KB)
  PM990.4100.00 Drawings (PDF 2.51MB)
 

C&D TECHNOLOGIES’ POWERCOM DIVISION’S ACM™-600 POWER PLANT
offers compact, reliable power for +24 Volt telecommunication needs. The power plant combines high power factor and highly efficient modular rectifiers, plug-in circuit breaker distribution, plant monitoring and alarm functions all into one system. Its flexible design can accommodate your current and future system needs with up to 360 Amperes and up to 600 Amperes with 150 Amp rectifiers. This advanced system is the optimal solution for small to medium telecommunication sites where space is limited.

Features and Benefits

  • State-of-the-Art Rectifiers: C&D Powercom advanced 24 Volt 150 Ampere modular rectifiers feature high efficiency, near unity power factor, and compact size. These hot-swappable modules can be easily installed without tools and without interrupting system operation.
  • Front Accessibility: All distribution and battery connections are front accessible, making this plant ideal for confined locations. The ACM-600 can be placed against a wall or in a confined area while still maintaining easy access to vital plant connections.
  • Distribution Features: The +24 Volt distribution section will accommodate up to a maximum 24 plug-in circuit breakers ranging from 5 to 100 Amperes. Circuit breakers 50 Amperes and less require one breaker position, circuit breakers 60 to 100 Amperes require two breaker positions, and 125 Ampere circuit breakers require three breaker positions.
  • Digital Metering: A 4½ digital ammeter/voltmeter is provided for fast and accurate system monitoring. An on-line test and calibration circuit utilizes the digital meter to set up and test alarm functions with no service interruptions.
  • Power Plant LEDs/Alarms: Standard power plant LEDs include: Power on, float/equalize status, major-minor alarms, high-low DC Voltage alarms, rectifier failure, LVD status, fuse alarms for +24 and -48 volt distribution, CFA alarm for converter failure, and optional high temperature alarm. Standard alarm form "C" contacts include: major (2 sets), minor, high DC Voltage, low DC Voltage, load circuit breaker trip, LVD status and optional high temperature.
  • Optional Low Voltage Disconnect: The optional low Voltage Disconnect protects the load from low Voltage and the system batteries from damage due to over discharge.
  • Optional Temperature Compensation and High Temperature Alarm: High temperature can damage and shorten the battery life. This option will automatically monitor and adjust the rectifier output Voltage to compensate for variations in battery temperature.
  • Optional DC-DC Converters: Up to five, 3-ampere modular converters are easily installed for low cost growth for -48 volt DC needs.
  • Space Saving Design: The ACM-600 Power Plant can be configured for mounting directly on top of C&D Powercom Liberty® Series 2000 VRLA batteries to save valuable floor space.